What size air conditioner do I need?
A quick way to work out a starting size for your room, what pushes it up or down, and why a bigger unit isn’t the safer choice.

For a typical room with a 2.4 m ceiling, allow about 0.1 kW of cooling for every square metre of floor. Multiply the room’s length by its width, then use this table to see which standard size that points to.
| Floor area | Starting size | Often suits |
|---|---|---|
| Up to 25 m² | 2.5 kW | Bedrooms, small offices, garden rooms |
| 25–35 m² | 3.5 kW | Large bedrooms, lounges |
| 35–50 m² | 5.0 kW | Large lounges, open-plan rooms |
| 50–66 m² | 6.6 kW | Open-plan living, small commercial rooms |
If you see sizes in BTU, 9,000 BTU is about 2.6 kW and 12,000 BTU is about 3.5 kW.
Then adjust for the room
Two rooms with the same floor area can need different systems. The table is where to start, not where to stop.

Ceiling height is the easiest to allow for: a room with a 3 m ceiling holds a quarter more air than one with a 2.4 m ceiling, so add about a quarter to the figure. A south-facing conservatory or a loft room under the roof will usually need more than its floor area suggests.
Why bigger isn’t better
It’s tempting to go up a size to be safe. But a unit that’s too large for the room reaches the set temperature quickly and then keeps easing back or cycling off. It spends less time drying the air, so the room can feel cool but clammy, and the extra starts add wear. Modern inverter units can slow right down, but only so far.
A unit that’s too small has the opposite problem: it runs flat out on the warmest days and may still not get there.
If you’ll use it for heating
Cooling and heating are separate calculations, and in Northern Ireland the heating need can be the bigger of the two. If heating matters to you, say so at the start. Our article on heating with air conditioning explains why.
Know your room’s size and roughly what it’s used for? Send us the details and we’ll tell you what we’d suggest.